CTD - Conductivity Temperature Depth : CTD Plus


CTD - Conductivity Temperature Depth : CTD Plus : Description


Updated in mid-2004, the CTD Plus was originally launched in 1992 and has seen extensive use in varying conditions and applications around the globe. The instrument is a rugged, intelligent CTD designed for precision measurements of conductivity, temperature and depth. It is delivered ready-to-use, and includes an aluminum shipping case, 2m data / power pigtail, batteries, a sensor protection cage, a dummy plug, a maintenance kit, manuals and software.

In this configuration, the CTD Plus is a rugged, intelligent CTD designed for precision measurements of conductivity, temperature, depth, and dissolved oxygen. The YSI dissolved oxygen sensor - located externally to the CTD for ease of maintenance and replacement - has a 60 second response time, acceptable for an in-situ application. More rapid DO response times are available with upgrade to other DO sensors.

Given the in-situ application, the pressure sensor accuracy is 0.15%, but can be upgraded to 0.05% or 0.01%FS. The Delrin housing provides freedom from zincs, helping to elongate maintenance cycles.

Like all Pluses, the new CTD Plus is designed for modularity. Any remote sensor purchased for use with the new Plus can be used with other Applied Microsystems Plus or Micro instruments. For example, a dissolved oxygen sensor originally purchased for vertical profiling use with a CTD Plus can be easily connected to an externally powered Micro CTD and deployed on AUVs, ROVs, or other platforms. Moreover, In the new Plus, remote sensors are no longer assigned to specific connectors on the instrument end-cap. Any analog (or digital or TTL) sensor can be plugged into any analog (or digital or TTL) connector, greatly simplifying field maintenance.

The new Plus comes standard with USB download capability to accelerate access to data once the instrument has been removed from water. Access to the USB port is via a removable threaded cap, which will expose the USB connector. The USB connector itself is located in a water-blocked heade

CTD - Conductivity Temperature Depth : CTD Plus : Summary Information:


Name:CTD Plus
Category:CTD - Conductivity Temperature Depth
Model:Plus
Number:n/a
Description:Updated in mid-2004, the CTD Plus was originally launched in 1992 and has seen extensive use in varying conditions and applications around the globe. The instrument is a rugged, intelligent CTD designed for precision measurements of conductivity, temperature and depth. It is delivered ready-to-use, and includes an aluminum shipping case, 2m data / power pigtail, batteries, a sensor protection cage, a dummy plug, a maintenance kit, manuals and software.

In this configuration, the CTD Plus is a rugged, intelligent CTD designed for precision measurements of conductivity, temperature, depth, and dissolved oxygen. The YSI dissolved oxygen sensor - located externally to the CTD for ease of maintenance and replacement - has a 60 second response time, acceptable for an in-situ application. More rapid DO response times are available with upgrade to other DO sensors.

Given the in-situ application, the pressure sensor accuracy is 0.15%, but can be upgraded to 0.05% or 0.01%FS. The Delrin housing provides freedom from zincs, helping to elongate maintenance cycles.

Like all Pluses, the new CTD Plus is designed for modularity. Any remote sensor purchased for use with the new Plus can be used with other Applied Microsystems Plus or Micro instruments. For example, a dissolved oxygen sensor originally purchased for vertical profiling use with a CTD Plus can be easily connected to an externally powered Micro CTD and deployed on AUVs, ROVs, or other platforms. Moreover, In the new Plus, remote sensors are no longer assigned to specific connectors on the instrument end-cap. Any analog (or digital or TTL) sensor can be plugged into any analog (or digital or TTL) connector, greatly simplifying field maintenance.

The new Plus comes standard with USB download capability to accelerate access to data once the instrument has been removed from water. Access to the USB port is via a removable threaded cap, which will expose the USB connector. The USB connector itself is located in a water-blocked heade
Configuration:Dissolved oxygen - YSI
Application:Ideal for long-term salinity studies that incorporate a requirement for dissolved oxygen. NB: Shallow water studies only. For deep water applications, upgrade of the DO sensor and Delrin mechanical housing are required.
Credibility Note:n/a
Case Study Link :n/a
Price:Consult factory


CTD - Conductivity Temperature Depth : CTD Plus : Usage Information:



Int Description:Plus - I- Logger - Delrin
Max Number Of Sensors:10 analog channels or 5 digital channels (NB: ability to integrate corresponding number of sensors a function of cumulative power requirements and available mounting / connector space)
Depth Rating:500m
Housing Material:Copolymer Acetal (Delrin)
Weight Air:n/a
Weight Water:n/a
Length:561 (length of pressure housing from retainer ring / fender to sensor end cap) OR 706 from end to end (including sensors, shackle, etc.)
Diameter:100
Power Source :Battery / External
Housing Notes:Dimensions and weight do not include any additional remote sensors that might be added to the configuration.

In this configuration of the Plus a USB connector is included to facilitate high speed data download.

The standard connector is a Subconn Micro 8 wet pluggable connector. Other connector choices can be accommodated, if desired.


CTD - Conductivity Temperature Depth : CTD Plus : Sensor Information:



Name:Temperature
Manufacturer:Applied Microsystems
Type:Thermistor
Model:n/a
Accuracy:0.005C
Range:-2 to 32C
Response Time:500ms
Max. Frequency:25Hz
Maximum Depth(m):n/a
Resolution:0.001c
Stabilityn/a
Location:n/a
Notes:Made of stainless steel

Name:Pressure
Manufacturer:Keller
Type:Semiconductor bridge strain gauge
Model:PA-10
Accuracy:0.15%FS
Range:Various to 6000 dbar
Response Time:10ms
Max. Frequency:25Hz
Maximum Depth(m):6000m
Resolution:0.005%FS
Stabilityn/a
Location:n/a
Notes:n/a

Name:Conductivity
Manufacturer:Applied Microsystems
Type:Conductive
Model:n/a
Accuracy:0.01 mS/cm; 0.005 mS/cm precision
Range:0 - 7 S/m or 0 - 70 mS/cm
Response Time:25ms @ 1m/s
Max. Frequency:25Hz
Maximum Depth(m):6000m
Resolution:0.0015 mS/cm
Stabilityn/a
Location:n/a
Notes:The Applied Microsystems conductivity sensor is short, with a length of just under 3 cm. Sensor length plays a critical role in determining resistance to the introduction of new flows into the sensor cavity, and hence response times. The equation for response time is as follows:

Response Time = (0.85 * Length of Sensor ) / Flow Speed.

Using the above, our conductivity sensor has a response time of 25 milliseconds in a 1.0 m/second flow environment and 255 milliseconds in a 0.1 m/second flow environment. Given the above, no pumps or flow tubes are required.

Name:Dissolved Oxygen
Manufacturer:YSI
Type:Polarographic
Model:n/a
Accuracy: 0.2 mg/l
Range:0 to 15 mg/l
Response Time:60s
Max. Frequency:Varies by CTD model (25Hz Micro, 10Hz Smart, 8Hz Plus)
Maximum Depth(m):300
Resolution:0.01 mg/l
Stabilityn/a
Location:n/a
Notes:n/a


Click here for the full list of Applied Microsystems products

 

 

Applied Microsystems Ltd. 2071 Malaview Ave.W. Sidney, BC, Canada V8L 5X6
Contact Us: sales@AppliedMicrosystems.com Tel:+1-250-656-0771 Fax:+1-250-655-3655