Chemical Contamination Of Water- Applied Microsystems
Chemical Contamination Of Water- Applied Microsystems
Capabilities- Applied Microsystems Services- Applied Microsystems Systems- Applied Microsystems Applications- Applied Microsystems

Home- Chemical Contamination Of Water- Applied MicrosystemsHome
News- Chemical Contamination Of Water - Applied MicrosystemsNews
Partners-  Chemical Contamination Of Water - Applied MicrosystemsPartners
Company-  Chemical Contamination Of Water - Applied MicrosystemsCompany
Support-  Chemical Contamination Of Water - Applied MicrosystemsSupport
Sitemap-  Chemical Contamination Of Water - Applied MicrosystemsSitemap
Contact-  Chemical Contamination Of Water - Applied MicrosystemsContact

 

 

 

 


CTD - Conductivity Temperature Depth : CTD Plus


CTD - Conductivity Temperature Depth : CTD Plus : Description


Updated in mid-2004, the CTD Plus was originally launched in 1992 and has seen extensive use in varying conditions and applications around the globe. The instrument is a rugged, intelligent CTD designed for precision measurements of conductivity, temperature and depth. It is delivered ready-to-use, and includes an aluminum shipping case, 2m data / power pigtail, batteries, a sensor protection cage, a dummy plug, a maintenance kit, manuals and software.

In this configuration, the CTD-12 Plus is a rugged, intelligent CTD designed for precision measurements of conductivity, temperature, depth, and dissolved oxygen. The dissolved oxygen sensor - located externally to the CTD for ease of maintenance and replacement - has rapid response times to assist in profiling.
Like all Pluses, the new CTD Plus is designed for modularity. Any remote sensor purchased for use with the new Plus can be used with other Applied Microsystems Plus or Micro instruments. For example, a dissolved oxygen sensor originally purchased for vertical profiling use with a CTD Plus can be easily connected to an externally powered Micro CTD and deployed on AUVs, ROVs, or other platforms. Moreover, In the new Plus, remote sensors are no longer assigned to specific connectors on the instrument end-cap. Any analog (or digital or TTL) sensor can be plugged into any analog (or digital or TTL) connector, greatly simplifying field maintenance.
The pressure sensor accuracy is 0.05% and can be upgraded to 0.01%FS. The sampling rate has been increased to 25Hz. The aluminium housing provides strength and protection from knocks and shocks.

The new Plus comes standard with USB download capability to accelerate access to data once the instrument has been removed from water. Access to the USB port is via a removable threaded cap, which will expose the USB connector. The USB connector itself is located in a water-blocked header.

CTD - Conductivity Temperature Depth : CTD Plus : Summary Information:


Name:CTD Plus
Category:CTD - Conductivity Temperature Depth
Model:Plus
Number:n/a
Description:Updated in mid-2004, the CTD Plus was originally launched in 1992 and has seen extensive use in varying conditions and applications around the globe. The instrument is a rugged, intelligent CTD designed for precision measurements of conductivity, temperature and depth. It is delivered ready-to-use, and includes an aluminum shipping case, 2m data / power pigtail, batteries, a sensor protection cage, a dummy plug, a maintenance kit, manuals and software.

In this configuration, the CTD-12 Plus is a rugged, intelligent CTD designed for precision measurements of conductivity, temperature, depth, and dissolved oxygen. The dissolved oxygen sensor - located externally to the CTD for ease of maintenance and replacement - has rapid response times to assist in profiling.
Like all Pluses, the new CTD Plus is designed for modularity. Any remote sensor purchased for use with the new Plus can be used with other Applied Microsystems Plus or Micro instruments. For example, a dissolved oxygen sensor originally purchased for vertical profiling use with a CTD Plus can be easily connected to an externally powered Micro CTD and deployed on AUVs, ROVs, or other platforms. Moreover, In the new Plus, remote sensors are no longer assigned to specific connectors on the instrument end-cap. Any analog (or digital or TTL) sensor can be plugged into any analog (or digital or TTL) connector, greatly simplifying field maintenance.
The pressure sensor accuracy is 0.05% and can be upgraded to 0.01%FS. The sampling rate has been increased to 25Hz. The aluminium housing provides strength and protection from knocks and shocks.

The new Plus comes standard with USB download capability to accelerate access to data once the instrument has been removed from water. Access to the USB port is via a removable threaded cap, which will expose the USB connector. The USB connector itself is located in a water-blocked header.
Configuration:Dissolved oxygen - Idronaut
Application:Vertical Profiling
Credibility Note:n/a
Case Study Link :n/a
Price:Consult factory


CTD - Conductivity Temperature Depth : CTD Plus : Usage Information:



Int Description:Plus - Profiler - Logger - 6061
Max Number Of Sensors:10 analog channels or 5 digital channels (NB: ability to integrate corresponding number of sensors a function of cumulative power requirements and available mounting / connector space)
Depth Rating:5000
Housing Material:6061-T6 Aluminum
Weight Air:9
Weight Water:3.5
Length:566 (length of pressure housing from retainer ring / fender to sensor end cap) OR 881 from end to end (including sensors, shackle, etc.)
Diameter:100
Power Source :Battery / External
Housing Notes:Dimensions and weight do not include any additional remote sensors that might be added to the configuration.

In this configuration of the Plus, a USB connector for high-speed data download capability is included as a standard.

The standard connector is a Subconn Micro 8 wet pluggable connector. Other connector choices can be accommodated, if desired.


CTD - Conductivity Temperature Depth : CTD Plus : Sensor Information:



Name:Pressure
Manufacturer:Keller
Type:Semiconductor bridge strain gauge
Model:PA-10
Accuracy:0.15%FS
Range:Various to 6000 dbar
Response Time:10ms
Max. Frequency:25Hz
Maximum Depth(m):6000m
Resolution:0.005%FS
Stabilityn/a
Location:n/a
Notes:n/a

Name:Temperature
Manufacturer:Applied Microsystems
Type:Thermistor
Model:n/a
Accuracy:0.005C
Range:-2 to 32C
Response Time:100milliseconds
Max. Frequency:25Hz on Plus & 8 Hz on Smart
Maximum Depth(m):5000m
Resolution:0.001C
Stabilityn/a
Location:n/a
Notes:n/a

Name:Pressure
Manufacturer:Keller
Type:Semiconductor bridge strain gauge
Model:PA-10
Accuracy:0.05%FS
Range:Various to 6000 dbar
Response Time:10ms
Max. Frequency:25Hz
Maximum Depth(m):6000m
Resolution:0.005%FS
Stabilityn/a
Location:n/a
Notes:n/a

Name:Dissolved Oxygen
Manufacturer:Idronaut
Type:Polarographic
Model:n/a
Accuracy: 0.2 mg/l
Range:0 to 15 mg/l
Response Time:3s
Max. Frequency:Varies by CTD model (25Hz Micro, 10Hz Smart, 8Hz Plus)
Maximum Depth(m):7000m
Resolution:0.01 mg/l
Stabilityn/a
Location:n/a
Notes:Idronaut states that maintenance (electrolyte and membrane replacement) should be carried out at least every three months. In-field calibration should be carried out after a long period of disuse, once a day during an extended field survey, or once a month if installed on a buoy profiler.

Name:Conductivity
Manufacturer:Applied Microsystems
Type:Conductive
Model:n/a
Accuracy:0.01 mS/cm; 0.005 mS/cm precision
Range:0 - 7 S/m or 0 - 70 mS/cm
Response Time:25ms @ 1m/s
Max. Frequency:25Hz
Maximum Depth(m):6000m
Resolution:0.0015 mS/cm
Stabilityn/a
Location:n/a
Notes:The Applied Microsystems conductivity sensor is short, with a length of just under 3 cm. Sensor length plays a critical role in determining resistance to the introduction of new flows into the sensor cavity, and hence response times. The equation for response time is as follows:

Response Time = (0.85 * Length of Sensor ) / Flow Speed.

Using the above, our conductivity sensor has a response time of 25 milliseconds in a 1.0 m/second flow environment and 255 milliseconds in a 0.1 m/second flow environment. Given the above, no pumps or flow tubes are required.


Click here for the full list of Applied Microsystems products

 

 

Applied Microsystems Ltd. 2071 Malaview Ave.W. Sidney, BC, Canada V8L 5X6
Contact Us: sales@AppliedMicrosystems.com Tel:+1-250-656-0771 Fax:+1-250-655-3655