Tide Wave : TWG-12


Tide Wave : TWG-12 : Description


The TWG-12 is a tried and true Tide & Wave Gauge with a high accuracy, high resolution quartz pressure transducer and precision thermistor. The unit is self-contained and can be bottom mounted.

Tide Wave : TWG-12 : Summary Information:


Name:TWG-12
Category:Tide Wave
Model:Plus
Number:n/a
Description:The TWG-12 is a tried and true Tide & Wave Gauge with a high accuracy, high resolution quartz pressure transducer and precision thermistor. The unit is self-contained and can be bottom mounted.
Configuration:-
Application:Tide & wave surveys for hydrographic survey correction, tidal measurements, detection of storm surge, etc.
Credibility Note:n/a
Case Study Link :n/a
Price:Consult factory


Tide Wave : TWG-12 : Usage Information:



Int Description:TWG Housing
Max Number Of Sensors:5
Depth Rating:600
Housing Material:Copolymer Acetal (Delrin)
Weight Air:6
Weight Water:3.9
Length:724 (overall length including sensors)
Diameter:100
Power Source :Battery / External
Housing Notes:Internal


Tide Wave : TWG-12 : Sensor Information:



Name:Temperature
Manufacturer:Applied Microsystems
Type:Thermistor
Model:n/a
Accuracy:0.05C
Range:-2 to 32C
Response Time:1 second
Max. Frequency:n/a
Maximum Depth(m):5000m
Resolution:0.001C
Stabilityn/a
Location:n/a
Notes:n/a

Name:Pressure
Manufacturer:ParoScientific
Type:Quartz crystal
Model:DigiQuartz
Accuracy:0.01%FS
Range:Various to 285 dbar
Response Time:Variable
Max. Frequency:8Hz
Maximum Depth(m):250m
Resolution:0.000001%FS
Stabilityn/a
Location:n/a
Notes:n/a